Vax - 18m Extension Cord + Vax Backpack Vacuum (VXCB-01)
The 18m orange extension cord can arc internally if the conductors break resulting in overheating and sparking.
| Identification |
18m Orange Extension Cord Sold With a Vax Bagged Backpack Vacuum Cleaner Model Number: VXCB-01 Sold approximately: 1st July 2018 – 18th March 2026 |
| Defect | The 18m orange extension cord can arc internally if the conductors break resulting in overheating and sparking. This poses a risk of serious injuries or death, and damage to property. |
| Hazards |
Risk of serious injury from burns or property damage if the extension cord overheats or sparks. Incidents resulting in injury have occurred. |
| Action Required | Stop using the 18m orange extension cord immediately and remove it from the Vax bagged backpack vacuum.
Contact Techtronic Industries for more information and instructions on how to destroy the cord and receive a voucher to purchase a replacement cord. Do not return the cord to your place of purchase. The Vax Bagged backpack vacuum cleaner unit is not being recalled and can be used without the 18m extension cord. Please Note: only the extension cord is being recalled, the Vax Bagged backpack vacuum cleaner unit is not being recalled. The extension cord was not sold separately. |
| Contact |
Techtronic Industries Australia Pty Ltd |
For more information, please click here.
Panasonic - Smart Pet Feeder (CP-JNF01FW) & Smart Water Fountain (CP-JNW01FW) Power Adaptors
The Smart Pet Feeder (CP-JNF01FW) & Smart Water Fountain (CP-JNW01FW) have potential risk that the Power Adaptor plug may break apart and expose live parts.
| Identification | Panasonic Power Adaptor Model Number: PS06H50K1000AD with Batch Numbers: 2320, 2322 & 2401 Sold approximately 17th August 2023 – 8th November 2024 |
| Defect | Potential risk that the Power Adaptor plug may break apart and expose live parts. This poses a risk of serious injuries or death, and damage to property. |
| Hazards | Risk of electric shock or serious Injury. |
| Action Required | Stop using the product immediately, switch off at the power point and then check the product for the affected part number and batch number. If the product has the affected part number and batch number, then please contact Panasonic Australia by telephone or email with the details to organise a free of charge replacement Power Adaptor and to organise to return the recalled Power Adaptor. |
| Contact | Please direct all calls and queries concerning this recall to Panasonic Australia Pty Ltd on Phone: 1800 062 255 (Toll-Free), email: ccc@panasonic.mailus.com.au or webform: https://au.panasonic.com.au/support/contact-us |
For more information, please click here.
Beefeater - Fridges (BS28200 & BS28130 Beverage Chillers)
The BS28200 & BS28130 refrigerator may have a fault which can cause it to catch on fire. This poses a risk of serious injuries or death, and damage to property.
| Identification | Model Numbers: BS28200 & BS28130. Serial Number ranges: 72900000 to 95299999, and 00100000 to 04599999 only. Certificate number SGS/180357, OTR200146, OTR200271. Sold approximately July 2017 – November 2021 (Manufactured July 2017 - November 2020) |
| Defect | The refrigerator may have a fault which can cause it to catch on fire. This poses a risk of serious injuries or death, and damage to property. |
| Hazards | There have been multiple fires in these refrigerators causing property damage and injury |
| Action Required | Turn the refrigerator off immediately and unplug it from the electricity supply. Contact Electrolux to arrange for a full refund. |
| Contact | Contact Electrolux Home Products toll-free number 1800 001 218 between 8am and 7pm AEST Mon-Fri or email productrecall@electrolux.com or visit www.beefeaterbbq.com/en-au/support-page/product-recall/ |
For more information, please click here.
Bissell - Cordless Wet Dry Vacuum Floor Cleaners (Models 2582H and 2588F)
Bissell advise they have recalled their Cordless Wet Dry Vacuum Floor Cleaners (model numbers 2582H and 2588F). This is due to an electrical safety issue where some circuit boards in the battery may overheat and catch fire, with a risk of fire or burns.
| Identification | Cordless wet/dry combination vacuum floor cleaners (model numbers 2582H and 2588F). Model numbers can be found on the rating label behind the water tank. You need to remove the water tank to see the rating label. Recalled models were sold between 1 June 2019 and 30 September 2022. |
| Defect | In rare instances, some battery management circuit boards may be susceptible to localized hot spots. |
| Hazards | Risk of overheating and possible risk of fire. |
| Action Required |
|
| Contact | Follow the actions required for replacement. Please call our Product Recall hotline on 1300 393 035 should you have any further questions. |
For more information, please click here.
Sunbeam - Aeroglide Rapid SR6370 Iron
Sunbeam advise that they have identified a limited batch of Aeroglide Rapid SR6370 Steam irons IPN 665886 that don't meet Australian Safety standard 60335.2.3.
| Identification | Aeroglide Rapid model number SR6370, type 1128 2000 – 2400W, and the date code 5216. |
| Defect | This is an isolated issue that effects a small number of irons sold from 11th Jan - 30th June 2017. |
| Hazards | Did not meet quality and safety standards. |
| Action Required | Stop using the machine, and return the product to Sunbeam for a full refund or a higher valued product replacement. |
| Contact | Please contact Sunbeam Consumer Service on 1300 138 774, Monday-Thursday 8:30am-5pm AEST, and Friday 9:30am-5pm AEST. |
For more information, please click here.
Breville - Fast Slow Cooker
In 2016 the BPR200 Fast Slow Cooker was recalled due to a product safety concern related to its Lid Gasket.
| Identification | Units sold between October 2010 and 2015 through electrical retailers and department stores nationally. Production date code (PDC) 1034 - 1511 inclusive of the production date can be found within the rating label. The rating label is located on the back of the unit. Only BPR200 units with a white silicone lid gasket are affected. |
| Defect | People have been injured because pressure has built up and released unexpectedly when the white lid gasket has been inserted in the wrong orientation, and contrary to the instructions manual. |
| Hazards | Scalding - incorrect fitting of the supplied white lid gasket may result in release of hot liquids. |
| Action Required |
Customers can continue to use the appliance safely by following these easy instructions: Check that the lid gasket is installed correctly before each use. Instructions are provided in the appliance instruction manual and can also be found at www.breville.com.au/recall. |
| Contact | Consumers should contact Breville on 1300 727 424 (8.30am - 5pm AEST, Mon - Fri), email recall@breville.com.au or visit www.breville.com.au/recall to arrange a new lid gasket kit which will be sent by Breville, free of charge. |
For more information, please click here.
Kenwood - Food Processor
A quality issue has been identified that impacts Kenwood Food Processor Models FPM800 and FPM810 regarding the "Julienne" disc.
| Identification | Kenwood have issued a recall for Food Processor models FPM800 and FPM810 manufactured from January 2019 through December 2021 that include the affected "Julienne" disc. |
| Defect | The "Julienne" disc may detach. This is an isolated issue and no other discs or food processors are affected. |
| Hazards | Potential ingestion risk. |
| Action Required |
We ask customers to stop using the "Julienne" disc and register through the Kenwood website for a free replacement disc. Registration and additional information is available at juliennedisc.kenwoodworld.com |
| Contact | For further information contact Kenwood customer support on +61 280 152 479 or visit the customer support section of the website www.kenwoodworld.com |